Table of Contents

Advertisement

6-5. Auto Seq Time

CDR-16T have a user programmable sequential switcher that determines how long a channel or
split pattern channel group is output to the monitor before switchover (camera dwell time) to the
next channel or channel group in the s equence. See sec. '5-1. Accessing MAIN Menu' for
information on making menu selections.
‡@
‡A
Where:
‡@ SPLIT
Sets time between switchover of split pattern groups when split pattern display selected and
auto sequence initiated. Setting range is 1 – 30 sec. See sec. '4-5-4. Channel Group Auto
Sequence' for switchover examples.
‡A FULL
Sets switchover time for each full screen camera channel when full screen display selected and
auto sequence initiated. If any channel set to 0 sec., result will be the same as when channel is
skipped (no display). Setting range is 0 – 30 sec. See sec. '4-4-2. Auto Sequence' for switchover
example.
A dwell time setting of 0 sec. for full screen channels will
effect split screen auto sequence as follows: If channel
group has at least 1 other input (full screen dwell time not
set to 0 sec.) not displayed as black, channel group auto
sequences according to split screen dwell time setting.
Channel set to 0 sec. (full screen dwell time) is displayed.
If channel group has all other inputs displayed as black,
channel group automatically skipped during auto
sequence. See sec. '4-5-4. Channel Group Auto
Sequence' for more details and examples.
[AUTO SEQ TIME]
SPLIT–1S
FULL
CH1--
5S
CH2--
CH3--
5S
CH4--
CH5--
5S
CH6--
CH7--
5S
CH8--
CH9--
5S
CH10-
CH11-
5S
CH12-
CH13-
10S
CH14-
CH15-
10S
CH16-
SET
EXIT
Important
69
3S
3S
3S
0S
3S
0S
10S
10S

Advertisement