Polycom Collaboration Server (RMX) 1500 Deployment Manual page 13

Collaboration server deployment guide for maximum security environments
Hide thumbs Also See for Collaboration Server (RMX) 1500:
Table of Contents

Advertisement

2
3
Polycom, Inc.
Position the Rack Spacer (item no. 3) onto the marked rack post together with left rack
rail runner (item no. 1 which is labeled LEFT) and fasten the flat head screws 3*10mm
(item no. 4) as shown in the following figure:
Figure 1-2
Detail of Front Rack Spacer Assembly (left rail runner is shown here) for all RMX
types
On the RMX1500/4000 the center hole on the Rack Spacer must be left clear as it is required for
fixing the RMX to the rack post. See Figure 1-2.
On the RealPresence Collaboration Server (RMX) 2000 the top hole on the Rack Spacer must
be left clear as it is required for fixing the RMX to the rack post. See Figure 1-2.
Adjust the telescopic rack rail runner to the rack opening and mount it onto the marked
position of the rear post as described in step 2.
Figure 1-3
Detail of Rear RealPresence Collaboration Server (RMX) 1500/2000/4000 Rack
Spacer Assembly
Chapter 1-First Time Installation and Configuration
1-7