Lucent Technologies MERLIN LEGEND Release 5.0 System Programming Manual page 577

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 5.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 5.0
System Programming 555-650-111
4
Programming Procedures
PRI Facilities
NOTE:
NOTE:
NOTE:
If you enter an invalid timer value, the number you enter is truncated to the
closest valid value. For example, if you enter 45 for a counter that ranges
from 0 to 30, 4 is recorded as the counter value.
Table 4-2
for each threshold.
Summary: Timers and Counters
Programmable by
Mode
Idle Condition
Planning Form
Factory Setting
Valid Entries
Inspect
Copy Option
Console Procedure
PC Procedure
Table 4-2.
Timers and Counters
Timer/Counter
Purpose
T200 Timer
Maximum response time
T203 Timer
Maximum time
N200 Counter
Maximum transmissions
N201 Counter
Maximum octets
K Counter
Maximum outstanding
I-frames
T303 Timer
Set up timeout
shows the factory setting for each timer and counter and the valid range
System Manager
All
Not required
Form 3b, Incoming Trunks: DS1 Connectivity
(100D module)
See
Table 4-2
See
Table 4-2
No
No
LinesTrunks
no.
Enter
ms/octets/and so on
timer/counter
on
4
PRI
Protocol
Timers
Select timer/counter
Enter
Exit
Type slot no.
+
Type no. of ms/octets/and so
Factory Setting
1 second
30 seconds
3 transmissions
260 octets
7 frames
4 seconds
Issue 1
June 1997
Page 4-170
Dial slot
Drop
Dial no. of
Exit
Exit
Exit
Select
Valid Range
1000 to 3000 ms
1 to 60 seconds
1 to 5 transmissions
16 to 260 octets
1 to 15 frames
4 to 12 seconds
Continued on next page