MERLIN LEGEND Communications System Release 5.0
System Programming 555-650-111
3
Common Administrative Procedures

Optional Operator Features

Optional Operator Features
The procedures in this section affect feature programming for both DLC and QCC
operator positions and include the following:
Operator Hold Timer
DLC Operator Automatic Hold
QCC operator features are covered in the next section.
Operator Hold Timer
Use this procedure to set the length of the operator hold timer for all DLCs and
QCCs. If the system operator does not pick up the call within the time
programmed, an abbreviated ring reminds the operator that a call is being held.
This option cannot be programmed for individual operator positions.
Summary: Operator Hold Timer
Programmable by
Mode
Idle Condition
Planning Form
Factory Setting
Valid Entries
Inspect
Copy Option
Console Procedure
PC Procedure
Procedure: Operator Hold Timer
Console Display/Instructions
Select the Operator menu.
 
System Programming:
Make a selection
System
SysRenumber
Operator
LinesTrunks
Exit
System Manager
All
Not required
Form 6a, Optional Operator Features
60 seconds
10 to 255 seconds
No
No
Operator
Hold Timer
seconds
Enter
Additional Information
>
Extensions
Options
Tables
AuxEquip
NightSrvce
3
3
3
Drop
Dial no. of
Exit
+
Type no. of seconds
3
Issue 1
June 1997
Page 3-25