5250 Options - Neoware c50 - Thin Client User Manual

Teemtalk 5.0 for unix
Hide thumbs Also See for Neoware c50 - Thin Client:
Table of Contents

Advertisement

Setup Menus

5250 Options

This dialog box is displayed by clicking the 5250 Options button in the Telnet
Options dialog box when TN5250 is not suppressed and the Model option in the IBM
5250 Settings dialog box is not set to 3812-1 (a printer). Refer to the next section for
5250 Printer Options.
Device Name
This enables you to enter the name of the device which the server will be requested to
assign to this Telnet session.
You can return the local host name by entering %s after the device name. To return the
user name, enter %u after the device name. You can specify how many characters of
the name is returned in each case. For example, %.3s will return the first three
characters of the local host name, and %-.3s will return the last three characters.
To automatically assign a new device name for each successive connection enter
%dN% after the name, where N is a decimal value. Each time the host requests the
device name a counter will be incremented modulus N and substituted into the device
name.
For example, TEST%d4% will give TEST1 on first connect, TEST2 on second,
TEST3 on third, TEST0 on fourth, TEST1 on fifth and so on.
TEST%d100% will give TEST1 on first connect, TEST2 on second, ... TEST99 on
99th, TEST0 on 100th, TEST1 on 101st and so on.
These values are preserved over power off, so the first connection of any given power
on may not be TEST1. Assume that the start point is random. In addition there is a
single counter for the unit so concurrent sessions will start from subsequent values. For
example, if session one uses TEST1 then session two will use TEST2.