Figure 42. Installing The Heatsink - Intel SR1625UR - Server System - 0 MB RAM Service Manual

Server system
Hide thumbs Also See for SR1625UR - Server System - 0 MB RAM:
Table of Contents

Advertisement

To install the heatsink, follow these steps:
1. Remove the protective film on the TIM if present.
2. Orient the heatsink over the processor as shown in
must be positioned as shown to provide correct airflow through the system.
3. Set the heatsink over the processor, lining up the four captive screws with the four
posts surrounding the processor.
4. Loosely screw in the captive screws on the heatsink corners in a diagonal manner
according to the numbers shown in
a. Starting with the screw at location 1, engage the screw threads by giving it two
b. Proceed to the screw at location 2 and engage the screw threads by giving it two
c. Engage screws at locations 3 and 4 by giving each screw two rotations and then
d. Repeat steps 4a through 4c by giving each screw two rotations each time until all
56
rotations in the clockwise direction and stop. (IMPORTANT: Do not fully
tighten.)
rotations and stop.
stop.
screws are lightly tightened upto a maximum of 8 inch-lbs torque.
2
TIM

Figure 42. Installing the Heatsink

Figure
42. The heatsink fins
Figure 42
as follows:
3
1
4
AF002841
®
Intel
Server System SR1625UR Service Guide