Installing The Midplane Board; Figure 59. Removing The Midplane From The Server System - Intel SR1625UR - Server System - 0 MB RAM Service Manual

Server system
Hide thumbs Also See for SR1625UR - Server System - 0 MB RAM:
Table of Contents

Advertisement

5. Remove the power distribution board cover. For instructions, see
Power Distribution Module" on page
6. Unscrew the thumbscrew (see letter "A" in
7. Hold the midplane board only by the edges and slide the midplane board in the
direction shown to release it from the backplane (see letter "B" in
8. Lift the midplane board over the retention pins (see letter "C" in
of the server system (see letter "D" in

Installing the Midplane Board

To install the midplane board, follow these steps:
1. Lower the midplane board into the system and position the midplane board over the
retention pins (see letter "A" in
2. Align the four holes on the midplane with the four standoffs on the chassis and
press down uniformly until it clicks into place (see letter "B" in
3. Slide the midplane board in the direction shown (see letter "C" in
insert the midplane into the backplane connector.
4. Tighten the thumbscrew (see letter "D" in
®
Intel
Server System SR1625UR Service Guide
B

Figure 59. Removing the Midplane from the Server System

84.
Figure
59).
Figure
59).
C
Figure
60) .
Figure
60).
"Replacing the
Figure
59).
Figure
59) and out
D
AF002859
Figure
60).
Figure
60) and
A
71