12. Close the CPU load plate all the way (see letter "A" in
13. Close the socket lever completely and ensure that the load plate tab engages under
the socket lever when fully closed (see letter "B" in
14. Install the heatsink. For instructions, see

Installing the Heatsink

You must install the processor before installing the heatsink. For instructions, see
"Installing the Processor" on page
Caution: Improper installation can damage the heatsink. Pay close attention to the steps and
perform each step exactly as indicated to avoid damage.
Caution: The heatsink has Thermal Interface Material (TIM) located on the bottom of it. Use
caution when you unpack the heatsink so you do not damage the TIM.
Note: New unused heatsinks have adequate TIM on the bottom. If you are reusing a heatsink
from replacing a processor, make sure there is adequate TIM present on the heatsink to
support processor cooling.
®
Intel
Server System SR1625UR Service Guide
Orientation Notch

Figure 40. Installing the Processor

A

Figure 41. Closing the Load Plate

52.
A
Orientation Post
AF002839
Figure
41).
Figure
41).
B
AF002840
"Installing the Heatsink" on page
55.
55