Raid Support; Advanced Management Options; Intel® Remote Management Module 3 - Intel SR1625UR - Server System - 0 MB RAM Service Manual

Server system
Hide thumbs Also See for SR1625UR - Server System - 0 MB RAM:
Table of Contents

Advertisement

RAID Support

The server system provides an embedded SATA controller on the server board that is
accessible through the passive midplane. The SATA controller supports both 1.5 and 3.0
Gbps data transfer rates.
The BIOS Setup utility provides multiple drive configuration options on the Advanced |
ATA Controller setup page, some of which affect the ability to configure RAID. The
Onboard SATA Controller option is enabled by default. When this option is enabled, the
SATA Mode option can be set to either Legacy or Enhanced. The Legacy and Enhanced
modes affect the RAID configuration as follows:
Legacy supports four disk drives and does not provide RAID support.
Enhanced supports six disk drives and is required for RAID configurations.
When the enhanced mode is selected, you can choose to enable or disable "AHCI Mode"
or "Configure SATA as RAID". The Intel
enabled by the "Configure SATA as RAID" option. The Intel
Technology II feature provides RAID modes 0, 1, and 10.
For RAID 0, 1, and 10, enclosure management is provided over the bridge board.
If RAID 5 is desired, the optional Intel
installed. To enable RAID 5, this activation key is placed on the SATA Key connector that
is located at the left side of the server board. For information on installing the Intel
RAID Activation Key AXXRAKSW5 accessory to enable RAID 5, see
®
Intel
Integrated RAID Activation Key and the RAID Mini-DIMM" on page
For information on configuring RAID, see the Intel
included on the Intel

Advanced Management Options

Intel® Remote Management Module 3
The Intel
board and provides additional server management functionality to the server board.
This module provides a dedicated web server for viewing server information and remote
control of the system. It also provides Remote KVM Redirection and USB Media
Redirection allowing USB devices attached to the remote system to be used on the
managed server.
For instructions on installing the Intel
and Removing the Intel
30
®
Server Deployment Toolkit 3.0 CD.
®
Remote Management Module 3 plugs into a dedicated connector on the server
®
Remote Management Module 3" on page
®
Embedded Server RAID Technology II is
®
RAID Activation Key AXXRAKSW5 can be
®
RAID Software User's Guide that is
®