Internal Error Codes; Table A-3 Internal Error Codes - HP 2600fx - Optical Disk Drive Command Reference Manual

Optical drive and library for fx, ex and mx models
Hide thumbs Also See for 2600fx - Optical Disk Drive:
Table of Contents

Advertisement

Internal Error Codes

NOTE
The XXXX that follows the internal error code refers to the 1 byte dsp/odc
error code where available.
Table A-3
Internal Error Codes
Error
Code
(hex.)
00070000
00080000
00080001
00080002
00080003
00080004
00090000
006B0000
02540000
012BXXXX
012CXXXX
012DXXXX
012EXXXX
012FXXXX
0130XXXX
0131XXXX
0133XXXX
Appendix A
Message
Medium was changed
Power on, reset, or bus device reset occurred (5.2 Gb drives)
Unit Attention: power on reset (9.1 Gb drives)
SCSI bus reset (9.1 Gb drives)
SCSI bus device reset message (9.1 Gb drives)
Autochanger reset (9.1 Gb drives)
Mode parameter changed
Microcode changed
Queued command cleared by another initiator
An invalid SCSI message was received
An invalid bit of Identify message is set to 1
Parity error was detected while receiving a SCSI message
A SCSI message was rejected
The Attention signal was asserted after the Message Out Phase
A SCSI interface parity error was detected
The Initiator Detected Error Message was received
The offset of the synchronous data transfer is too large
Drive Error Codes
Internal Error Codes
A-9

Hide quick links:

Advertisement

Table of Contents
loading