Retry Log Data Format; Table 3-64 Retry Log Data Format - HP 2600fx - Optical Disk Drive Command Reference Manual

Optical drive and library for fx, ex and mx models
Hide thumbs Also See for 2600fx - Optical Disk Drive:
Table of Contents

Advertisement

Retry Log Data Format

This log is ONLY supported on the 40fx, 80ex, 125ex and 220mx models.
NOTE
This table can be accessed via the Log Sense Command (4DH),
Table 3-45 on page 3-47, with page code 39H.
Each retry algorithm code byte triggers a specific retry algorithm on the
preceding move command. The byte order is the same order in which the
retry algorithms were run.
Table 3-64
Retry Log Data Format
The last four bytes may be organized as two 16 bit words. The first word
is the cumulative number of Inline Retries (since the jukebox was built),
and the second word is the cumulative number of Major Retries (since
the jukebox was built). Inline Retries are attempts to move again from
the error position. Major Retries are attempts to move again after a Find
Home command has re-zeroed the unit.
Chapter 3
Byte
0
Page Code 39H
1
Reserved = 0
2-3
Number of bytes to follow
4-103
Retry Algorithm Code (Table 3-65 on page 3-62)
104-105
Number of Inline Retries
106-107
Number of Major Retries
Jukebox SCSI-2 Command Set
Log Sense Command (4DH)
Description
3-61