Read Element Status Data - HP 2600fx - Optical Disk Drive Command Reference Manual

Optical drive and library for fx, ex and mx models
Hide thumbs Also See for 2600fx - Optical Disk Drive:
Table of Contents

Advertisement

Starting Element
Address
Number Of
Elements
Allocation
Length

Read Element Status Data

Read Element Status Data consists of a data header, followed by one or
more Element Status pages.
Table 3-71
Read Element Status Data Header
Byte
0
1
2
3
4
5
6
7
Byte Count Report
Available
Chapter 3
Specifies the minimum element address to report.
Maximum number of elements to report.
The number of bytes of element status to return. The
data consists of an 8-byte Element Status Page Header,
followed by one or more Element Status pages.
7
6
5
First Element Address Reported (MSByte)
First Element Address Reported (LSByte)
Number of Elements Reported (MSByte)
Number of Elements Reported (LSByte)
Byte Count of Report Available (MSByte)
Byte Count of Report Available (Middle Byte)
Byte Count of Report Available (LSByte)
The number of bytes of element status page data
available.
Jukebox SCSI-2 Command Set
Read Element Status Command (B8H)
4
3
2
Reserved (0)
1
0
3-69