Performing a CP
Switchover
Step 1
Step 2
Step 3
Step 4
Step 5

Hot Swapping

June 2005
Voice/Data Interruption
Calls being set up during a forced switchover are dropped.
To perform a switchover:
Ensure that the standby CP card is "unlocked"
States
on page 11-9).
Select the active card.
Select Switchover from the Configuration menu or by right-
clicking the active card. A prompt appears, asking if you want to
continue the operation.
Click Yes to perform the switchover.
Observe the colors of the cards. The previously active card
becomes the standby card and the previously standby card is now
the active card.
Hot swapping lets you remove and replace cards without shutting
down and reconfiguring the CPX-1000. JetCraft supports hot
swapping on all cards.
To hot swap a MP card, go to page
To hot swap CP and HSC cards, go to page
To hot swap line cards, go to page
Note
Make sure to put on an anti-static wrist wrap when hot
swapping cards. Refer to CPX-1000 Voice Services
Platform Installation and Operation for more information.