Paradyne 8922 Installation And User Manual

Zhone 8922 network-accessory: user guide

Advertisement

Quick Links

8922 POTS Card
Installation and User's Guide
Document Number 8922-A2-GN10-10
November 2004
Contents
..........................................................................................................
................................................................................................ 12
................................................................................................. 15
................................................................................................... 21
.....................................................................
.......................................................................
.....................................................................................
..................................................................................
.........................................................................................
...................................................................... 12
................................................................................. 13
................................................................................... 14
.............................................................................. 15
................................................................................ 20
..................................................................................... 21
.................................................
........................................................... 15
........................................................ 18
............................................... 19
...................................... 21
1
2
4
5
6
6
8
9

Advertisement

Table of Contents
loading

Summary of Contents for Paradyne 8922

  • Page 1: Table Of Contents

    8922 POTS Card Installation and User’s Guide Document Number 8922-A2-GN10-10 November 2004 Contents Software and Firmware License Agreement Product Documentation Online 8922 POTS Card Description Installation Overview Installing POTS Cards Front Panel LEDs Cabling Web Interface ... 12 Web Interface – Configuration Web Interface –...
  • Page 2: Software And Firmware License Agreement

    Software and Firmware License Agreement ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS TERMS, YOU MAY USE THE SOFTWARE AND/OR FIRMWARE INCORPORATED INTO THE PARADYNE PRODUCT. BY USING THE PARADYNE PRODUCT YOU SHOW YOUR ACCEPTANCE OF THE TERMS OF THIS LICENSE AGREEMENT. IN THE EVENT THAT YOU DO NOT AGREE WITH ANY OF THE TERMS OF THIS LICENSE AGREEMENT, PROMPTLY RETURN THE UNUSED PRODUCT IN ITS ORIGINAL PACKAGING AND YOUR SALES RECEIPT OR INVOICE TO THE...
  • Page 3 5. Except for the Product warranty contained in the manual, the Software is provided “AS IS” and in its present state and condition and Paradyne makes no other warranty whatsoever with respect to the Product purchased by you. THIS AGREEMENT EXPRESSLY EXCLUDES ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, OR ORAL OR WRITTEN, INCLUDING WITHOUT LIMITATION: Any warranty that the Software is error-free, will operate uninterrupted in your...
  • Page 4: Product Documentation Online

    Product Documentation Online Complete documentation for this product is available at www.paradyne.com. Select Library → Technical Manuals. Document Number Document Title 8400-A2-GB20 Shelf Concentration and Processing (SCP) Card User’s Guide 8400-A2-GZ40 Shelf Concentration and Processing (SCP) Card Installation Instructions 8400-A3-GB21 8620 and 8820 Broadband Access Concentrators TL1 Reference 8400-A3-GB22...
  • Page 5: 8922 Pots Card Description

    8922 POTS Card Description The 8922 POTS (Plain Old Telephone Service) card can be used in any 8620 or 8820 Broadband Access Concentrator (BAC) managed by a Shelf Concentration and Processing (SCP) card. The model 8820-A2-520 BAC is required for test access.
  • Page 6: Installation Overview

    Installation Overview In the course of installing the 8922 POTS card, you will: ❑ Obtain the applicable cable; refer to ❑ Make sure the BAC is installed and power is supplied to the chassis. ❑ Install the card in the BAC.
  • Page 7 3. Holding the POTS card vertically with component side facing right, insert it into the top and bottom card guides. CAUTION: Do not force the unit into the slot. This could damage the backplane connectors. If the card does not seat properly, remove the card and reinstall it.
  • Page 8: Front Panel Leds

    Front Panel LEDs The following table describes the meaning and states of the LEDs on the front panel. Type LED is . . . * SYSTEM Green, On Green, Pulsing Alrm Amber, On Test Amber, On SYS BUS Green, Fast Blinking Green, Fast Blinking...
  • Page 9: Cabling

    Cabling The POTS card normally is connected to a 66 Block using a straight-through cable with two RJ21X plugs. The cable you need depends on the hardware configuration of the 66 Block or other connection point. See Attach the cable to the 50-pin Telco jack on the back of the DSLAM that is associated with the slot the POTS card resides in.
  • Page 10 Fastening a Cable with Locking Pivot Brackets Procedure To fasten a Telco connector to the chassis with locking pivot brackets: 1. Replace the longer captive screw on the cable connector with the #4-40 Phillips pan-head screw shipped in a plastic bag with the BAC chassis. 2.
  • Page 11 4. Insert the bottom edge of the locking pivot bracket inside the lower edge of the rear panel cutout next to that connector. Locking Pivot Bracket Rear Panel Receptacle on Backplane Cutout 99-16163d-01 5. Align the two connectors. 6. Rotate the connector until it is fully seated. Rotate 99-16163e-01 7.
  • Page 12: Web Interface

    Web Interface To access the web interface: Procedure 1. Open your web browser. (Internet Explorer Version 6 or above is recommended.) 2. Type http:// and the IP address of the SCP card into the Address field of your browser window. The default address is 10.10.10.10: 3.
  • Page 13: Web Interface - Status

    „ Configuration ➔ POTS ➔ IAD — Identification — Administrative State — Gateway Protocol (ATM interface only) — ATM Forum Predefined Profile (ATM) — Upstream Connection Slot (ATM) — Upstream Connection Port (ATM) — Upstream Connection VPI (ATM) — Upstream Connection VCI (ATM) —...
  • Page 14: Web Interface - Tests

    „ Status ➔ POTS (IP interface only) — Operational Status — Hook Status — Active Call Agent — Call Agent Name — Call Agent IP Address — Call Agent Signaling Port — Total Calls — Total Calls Failed ➔ „ Status IAD Statistics (ATM interface only) —...
  • Page 15: Tl1 Interface

    SCP cards with an IP uplink support a proprietary Command Line Interface (CLI). To use the CLI to configure, monitor, or test the 8922 POTS card: 1. Connect a PC with a terminal emulation program to the SERIAL SCP jack of your BAC.
  • Page 16 The schematic diagram below shows the TAP architecture of the SIM and the POTS card.
  • Page 17 The relay states associated with the TL1 commands are shown in Table 1 for a 4-wire configuration, and in Table 2 for a 2-wire configuration. Table 1. Relay States In 4-wire Configuration State or Command Default (no test) open CHG-SPLIT closed CHG-SPLIT-LILO E closed...
  • Page 18: Tl1 Interface And Cli Test Commands

    TL1 Interface and CLI Test Commands The TL1 interface supported by SCP cards with an ATM uplink and CLI supported by SCP cards with an IP uplink include the following commands related to MTAU and POTS testing: „ TL1: CHG-SPLIT CLI: test mtau chg-split –...
  • Page 19: Rj21X (Ca21A) Connector Pin Assignments

    RJ21X (CA21A) Connector Pin Assignments On the 8620 or 8820 BAC is a 50-pin RJ21X (CA21A) Telco connector, labeled DSL Ports 1–24, associated with the slot where the POTS card resides. It provides the 2-wire interface from each POTS port to the 66 Block. Table 3 lists the pin assignments for each of these interfaces.
  • Page 20: Technical Specifications

    Technical Specifications Table 4. Technical Specifications Specifications Approvals Safety Certifications Physical Environment Operating temperature Storage temperature Relative humidity Shock and vibration POTS Interface Signaling Transmission Dialing Loops Power Power Dissipation Size Test Access Voice Processing Encoding Echo Cancellation VoATM Protocol Weight Criteria Refer to the equipment’s label for approvals on product.
  • Page 21: Warranty, Sales, Service, And Training Information

    Warranty, Sales, Service, and Training Information Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods: „...
  • Page 24   " *8922-A2-GN10-10*...

Table of Contents