10 | Specifications
serve and ensure that the agreed reactive power can be delivered from any active power operating point. The graphic
shows the appropriate P-Q operating range with a required example active power of 48% of the maximum apparent
power of the plant or 43% of the maximum active power of the plant.
Fig. 69: P-Q operating range with limited active power (Qmax=Smax≠Pmax) Storage inverter
The power reduction parameters can be adjusted in SunSpec model DID123. During this process, you should also check
whether internal and/or external power reduction is active.
Internal power limitation
Status = active
Maximum apparent power S
92000 VA
Maximum active power P
= 80%
lim
(approx. 73600 W)
Tab. 7: Sample parameters for power limitation
If the ramp time "WMaxLimPct_RvrtTms" in the SunSpec model is specified as 0 s, then the internal output gradient is
used. Otherwise, the set value will be used.
Irrespective of the communication protocol used, the settling time "WMaxLim_Ena" is used in order to transfer the new
power value. Otherwise, the internally configured value will be used.
The additional ramp time "WMaxLimPct_RmpTms" specifies the jump time from a power value to the new power value.
The following formulae are used to calculate the gradient S
Power / kVA resp. kW
S
=100
lim
P
=80
lim
P
=60
fb
WMaxLimPct =40
Gradient = -600 % S
10
20
30
40
Fig. 70: Power gradient according to sample parameters and calculation
The following formulae are used to calculate the Q filter parameter and cos ϕ gradient:
Page 80
Parameters for external power limita-
tion
Status = active
=
lim
AC fallback active power Pfb = 75% P
(approx. 55200 W)
PT1 settling time = 1 s
/min
lim
Time / s
50
60
70
blueplanet gridsave 92.0 TL3-S blueplanet gridsave 110 TL3-S blueplanet gridsave 137
Manual
Parameters for power limitation
Parameters in SunSpec model 123:
"WMaxLimPct" = 50% P
"WMaxLimPct_RvrtTms" = 60 s
lim
"WMacLimPct_RmpTms" = 2 s
"WMaxLim_Ena" = 1
:
lim/min
(approx. 36800 W)
lim
TL3-S