4.1 Section Safety

4.1
Section Safety
Only let approved personnel install, wire, maintain, examine, replace parts, and repair the drive.
If personnel are not approved, it can cause serious injury or death.
Do not modify the drive body or drive circuitry.
Modifications to drive body and circuitry can cause serious injury or death, will cause damage to the drive, and will
void the warranty. Yaskawa is not responsible for modifications of the product made by the user.
Do not put flammable or combustible materials on top of the drive and do not install the drive near
flammable or combustible materials. Attach the drive to metal or other noncombustible material.
Flammable and combustible materials can start a fire and cause serious injury or death.
When you install the drive in an enclosure, use a cooling fan or cooler to decrease the temperature
around the drive. Make sure that the intake air temperature to the drive is 50 °C (122 °F) or less for
IP20/UL Open Type drives, and 40 °C (104 °F) or less for IP20/UL Type 1 drives.
If the air temperature is too hot, the drive can become too hot and cause a fire and serious injury or death.
Tighten terminal cover screws and hold the case safely when you move the drive.
If the drive or covers fall, it can cause moderate injury.
Do not let unwanted objects, for example metal shavings or wire clippings, fall into the drive during
drive installation. Put a temporary cover over the drive during installation. Remove the temporary
cover before start-up.
Unwanted objects inside of the drive can cause damage to the drive.
When you touch the drive and circuit boards, make sure that you observe correct electrostatic
discharge (ESD) procedures.
If you do not follow procedures, it can cause ESD damage to the drive circuitry.
Install vibration-proof rubber on the base of the motor or use the frequency jump function in the
drive to prevent specific frequencies that vibrate the motor.
Motor or system resonant vibration can occur in fixed speed machines that are converted to variable speed. Too
much vibration can cause damage to equipment.
You can use the drive with an explosion-proof motor, but the drive is not explosion-proof. Install
the drive only in the environment shown on the nameplate.
If you install the drive in a dangerous environment, it can cause damage to the drive.
Do not lift the drive with the covers removed.
If the drive does not have covers, you can easily cause damage to the internal parts of the drive.
216
WARNING
Electrical Shock Hazard
Fire Hazard
CAUTION
Crush Hazard
NOTICE
Damage to Equipment
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING