YASKAWA GA500 Maintenance & Troubleshooting page 48

Industrial ac microdrive
Table of Contents

Advertisement

2.4 Fault
Code
Name
Note:
• This fault occurs if the drive sensors detect a drive output current more than the specified overcurrent detection level.
• Do a Fault Reset to clear the fault.
Code
Name
oC2
Overcurrent2
Note:
• This fault occurs if the drive sensors detect a drive output current more than the specified overcurrent detection level.
• Do a Fault Reset to clear the fault.
Code
Name
oFA00
Option Not Compatible with Port
Note:
• Do a Fault Reset to clear the fault.
• Fault trace is not available for these faults.
Code
Name
oFA01
Option Fault/Connection Error
Note:
Do a Fault Reset to clear the fault.
Code
Name
Option Card Error Occurred at
oFA03
Option Port CN5
Note:
Do a Fault Reset to clear the fault.
Code
Name
Option Card Error Occurred at
oFA04
Option Port CN5
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFA05
Option Card Error Occurred at
Option Port CN5
Note:
Do a Fault Reset to clear the fault.
Code
Name
Option Card Error Occurred at
oFA06
Option Port CN5
Note:
Do a Fault Reset to clear the fault.
48
Causes
When you use an IE3 premium efficiency motor.
Causes
When A1-02 = 5, 6, 8 [Control Method Selection =
OLV/PM, AOLV/PM, or EZOLV], the output current
is more than the value set in L8-27 [Overcurrent
Detection Gain].
Causes
The option connected to connector CN5 is not
compatible.
Causes
You changed the option card connected to connector
CN5 during operation.
Causes
A fault occurred in the option card.
Causes
A fault occurred in the option card.
Causes
A fault occurred in the option card.
Causes
A fault occurred in the option card.
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
Possible Solutions
Use these values to adjust the parameters.
• b3-03 [Speed Search Deceleration Time] = default value × 2
• L2-03 [Minimum Baseblock Time] = default value × 2
• L2-04 [Powerloss V/f Recovery Ramp Time] = default value × 2
Possible Solutions
Correct the value set in L8-27.
Possible Solutions
Connect a correct option.
Possible Solutions
1.
De-energize the drive.
2.
Refer to the option card manual and correctly connect the
option card to the connector on the drive.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
Re-energize the drive. If the problem continues, replace the
option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
Re-energize the drive. If the problem continues, replace the
option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
Re-energize the drive. If the problem continues, replace the
option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
Re-energize the drive. If the problem continues, replace the
option card.

Advertisement