YASKAWA GA500 Maintenance & Troubleshooting page 207

Industrial ac microdrive
Table of Contents

Advertisement

Table 3.10 SSR1 Series Motor Code Setting for Specification of 200 V at 1750 min
No.
Name
PM Motor Code Selection
Voltage Class
E5-01
Capacity
Motor Rotation Speed
E5-02
PM Motor Rated Power
E5-03
PM Motor Rated Current (FLA)
E5-04
PM Motor Pole Count
PM Motor Resistance (ohms/
E5-05
phase)
E5-06
PM d-axis Inductance (mH/phase)
E5-07
PM q-axis Inductance (mH/phase)
PM Back-EMF Vpeak (mV/(rad/
E5-09
s))
PM Back-EMF L-L Vrms (mV/
E5-24
rpm)
E1-04
Maximum Output Frequency
E1-05
Maximum Output Voltage
E1-06
Base Frequency
E1-09
Minimum Output Frequency
L3-24
Motor Accel Time @ Rated
Torque
*1
n5-02
Motor Inertia Acceleration Time
n8-49
Heavy Load Id Current
*1
The default setting changes when the setting for o2-04 [Drive Model Selection] changes.
Table 3.11 SSR1 Series Motor Code Setting for Specification of 400 V at 1750 min
No.
Name
PM Motor Code Selection
Voltage Class
E5-01
Capacity
Motor Rotation Speed
E5-02
PM Motor Rated Power
PM Motor Rated Current
E5-03
(FLA)
E5-04
PM Motor Pole Count
PM Motor Resistance (ohms/
E5-05
phase)
PM d-axis Inductance (mH/
E5-06
phase)
PM q-axis Inductance (mH/
E5-07
phase)
PM Back-EMF Vpeak (mV/
E5-09
(rad/s))
PM Back-EMF L-L Vrms
E5-24
(mV/rpm)
E1-04
Maximum Output Frequency
E1-05
Maximum Output Voltage
E1-06
Base Frequency
E1-09
Minimum Output Frequency
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
3.22 Parameters Changed by E5-01 [PM Motor Code Selection]
Unit
-
120B
V
200
kW
7.5
min
-1
1750
kW
7.5
A
28.13
-
6
Ω
0.198
mH
4.15
mH
5.91
mVs/rad
258.2
-1
mV/min
0.0
Hz
87.5
V
190.0
Hz
87.5
Hz
4.4
s
0.077
s
0.077
%
-18.5
Unit
-
1232
1233
V
400
kW
0.4
min
-1
1750
1750
kW
0.4
A
0.89
-
6
Ω
25.370
9.136
mH
169.00
92.08
mH
197.50
119.56
mVs/rad
392.6
440.6
mV/min
-1
0.0
Hz
87.5
V
380.0
380.0
Hz
87.5
Hz
4.4
Motor Code (setting value of E5-01)
120D
120E
200
200
11
15
1750
1750
11.0
15.00
41.4
55.4
6
6
0.094
0.066
3.40
2.45
3.91
3.11
239.3
248.1
0.0
0.0
87.5
87.5
190.0
190.0
87.5
87.5
4.4
4.4
0.084
0.102
0.084
0.102
-10.9
-16.5
Motor Code (setting value of E5-01)
1235
1236
400
400
400
0.75
1.5
1750
1750
0.75
1.5
1.56
2.81
4.27
6
6
6.010
3.297
67.71
34.40
81.71
54.00
478.3
466.3
0.0
0.0
87.5
87.5
87.5
380.0
380.0
87.5
87.5
87.5
4.4
4.4
-1
(r/min)
120F
1210
200
200
18.5
22
1750
1750
18.50
22.00
68.2
80.6
6
6
0.051
0.037
2.18
1.71
2.55
2.05
253.6
250.0
0.0
0.0
87.5
87.5
190.0
190.0
87.5
87.5
4.4
4.4
0.101
0.098
0.101
0.098
-11.3
-12.8
-1
(r/min)
1238
123A
400
400
2.2
3.7
5.5
1750
1750
2.2
3.7
5.5
7.08
10.31
6
6
1.798
0.982
32.93
22.7
37.70
26.80
478.8
478.1
0.0
0.0
0.0
87.5
87.5
380.0
380.0
87.5
87.5
4.4
4.4
4.4
6
3
207

Advertisement

Table of Contents
loading

Table of Contents