YASKAWA GA500 Maintenance & Troubleshooting page 272

Industrial ac microdrive
Table of Contents

Advertisement

7.5 Drive Specifications
Item
Select from 15 pre-defined V/f patterns, or a user-set V/f pattern.
V/f Characteristics
Feed Forward Control, Restart After Momentary Power Loss, Speed Search, Overtorque Detection, Torque Limit, 17 Step Speed (max.), Accel/Decel Switch,
S-curve Acceleration/Deceleration, 3-wire Sequence, Auto-Tuning (Rotational and Stationary), Dwell Function, Cooling Fan ON/OFF Switch, Slip
Main Control
Compensation, Torque Compensation, Frequency Jump, Upper/Lower Limits for Frequency Reference, DC Injection Braking at Start and Stop, Overexcitation
Functions
Braking, High Slip Braking, PID Control (with Sleep Function), Energy Saving Control, MEMOBUS/Modbus Communications (RS-485 max, 115.2 kbps),
Auto Restart, Application Presets, DriveWorksEZ (customized functions), Parameter Backup Function, Online Tuning, KEB, Overexcitation Deceleration,
Overvoltage Suppression, High Frequency Injection, etc.
Item
Electronic thermal overload protection
Motor Protection
Momentary
Drive stops when the output current is more than 200% of the HD output current.
Overcurrent
Protection
Drive stops when the output current is more than these overload tolerances:
• HD: 150% of the rated output current for 60 seconds.
Overload Protection
• ND: 110% of the rated output current for 60 seconds.
Note:
If output frequency < 6 Hz, the drive can trigger the overload protection function when the output current is in the overload tolerance range.
Overvoltage
200 V Class: Stops when the DC bus voltage is more than approximately 410 V
Protection
400 V Class: Stops when the DC bus voltage is more than approximately 820 V
Single-phase 200 V class: Stops when the DC bus voltage decreases to less than approximately 160 V
Undervoltage
Three-phase 200 V class: Stops when the DC bus voltage decreases to less than approximately 190 V
Protection
Three-phase 400 V class: Stops when the DC bus voltage decreases to less than approximately 380 V
Stops when power loss is longer than 15 ms and continues operation if power loss is shorter than 2 s (depending on parameter settings).
Note:
Momentary Power
• Load size and motor speed can cause the stop time to be shorter.
Loss Ride-thru
• Drive capacity will change the continuous operation time. A Momentary Power Loss Recovery Unit is necessary to continue operation through a 2 s
power loss on models 2001 to 2042 and 4001 to 4023.
Heatsink Overheat
The drive stops when the thermistor detects an IGBT temperature more than approximately 100°C (212°F). The trip temperature level is different for different
Protection
drive models.
Braking Resistor
Overheat detection for braking resistor (optional ERF-type, 3% ED)
Overheat Protection
Stall Prevention
Stall prevention is available during acceleration, deceleration, and during run.
Electronic circuit protection
Note:
Ground Fault
This protection detects ground faults during run. The drive will not provide protection when:
Protection
• There is a low-resistance ground fault for the motor cable or terminal block
• There is a ground fault and you energize the drive
DC Bus Charge LED Charge LED illuminates when DC bus voltage is more than 50 V.
Item
Indoors
Area of Use
Overvoltage Category III
Power Supply
IP20/UL Open Type: -10 °C to +50 °C (14 °F to 122 °F)
IP20/UL Type 1: -10 °C to +40 °C (14 °F to 104 °F)
Ambient Temperature
• When you install the drive in an enclosure, use a cooling fan or air conditioner to keep the internal air temperature in the permitted range.
• Do not let the drive freeze.
95% RH or less
Humidity
Do not let condensation form on the drive.
Storage Temperature -20 °C to +70 °C (-4 °F to +158 °F) (short-term temperature during transportation)
Pollution degree 2 or less
Install the drive in an area without:
• Oil mist, corrosive or flammable gas, or dust
• Metal powder, oil, water, or other unwanted materials
Surrounding Area
• Radioactive materials or flammable materials, including wood
• Harmful gas or fluids
• Salt
• Direct sunlight
272
Specification
Table 7.9 Protection Functions
Specification
Table 7.10 Environment
Specification
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING

Advertisement

Table of Contents
loading

Table of Contents