3.9 F: Options
No.
Name
(Hex.)
F7-62
PZD3 Write
(0782)
F7-63
PZD4 Write
(0783)
F7-64
PZD5 Write
(0784)
F7-65
PZD6 Write
(0785)
F7-66
PZD7 Write
(0786)
F7-67
PZD8 Write
(0787)
F7-68
PZD9 Write
(0788)
F7-69
PZD10 Write
(0789)
F7-70
PZD1 Read (Status Word)
(078A)
F7-71
PZD2 Read (Output
Frequency)
(078B)
F7-72
PZD3 Read
(078C)
F7-73
PZD4 Read
(078D)
F7-74
PZD5 Read
(078E)
F7-75
PZD6 Read
(078F)
F7-76
PZD7 Read
(0790)
F7-77
PZD8 Read
(0791)
F7-78
PZD9 Read
(0792)
F7-79
PZD10 Read
(0793)
126
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD3 (PPO output). A
value of 0, 1, or 2 will disable the PZD3 (PPO output) write operation to the MEMOBUS/Modbus
register.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD4 (PPO output). A
value of 0, 1, or 2 will disable the PZD4 (PPO output) write operation to the MEMOBUS/Modbus
register.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD5 (PPO output). A
value of 0, 1, or 2 will disable the PZD5 (PPO output) write operation to the MEMOBUS/Modbus
register.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD6 (PPO output). A
value of 0, 1, or 2 will disable the PZD6 (PPO output) write operation to the MEMOBUS/Modbus
register.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD7 (PPO output). A
value of 0, 1, or 2 will disable the PZD7 (PPO output) write operation to the MEMOBUS/Modbus
register.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD8 (PPO output). A
value of 0, 1, or 2 will disable the PZD8 (PPO output) write operation to the MEMOBUS/Modbus
register.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD9 (PPO output). A
value of 0, 1, or 2 will disable the PZD9 (PPO output) write operation to the MEMOBUS/Modbus
register.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD10 (PPO output). A
value of 0, 1, or 2 will disable the PZD10 (PPO output) write operation to the MEMOBUS/Modbus
register.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD1 (PPO input). PZD1
(PPO input) functions as the ZSW when F7-70 = 0.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD2 (PPO input). PZD2
(PPO input) functions as the HIW when F7-71 = 0.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD3 (PPO input). A
value of 0 will disable the PZD3 (PPO input) load operation from the MEMOBUS/Modbus register.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD4 (PPO input). A
value of 0 will disable the PZD4 (PPO input) load operation from the MEMOBUS/Modbus register.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD5 (PPO input). A
value of 0 will disable the PZD5 (PPO input) load operation from the MEMOBUS/Modbus register.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD6 (PPO input). A
value of 0 will disable the PZD6 (PPO input) load operation from the MEMOBUS/Modbus register.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD7 (PPO input). A
value of 0 will disable the PZD7 (PPO input) load operation from the MEMOBUS/Modbus register.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD8 (PPO input). A
value of 0 will disable the PZD8 (PPO input) load operation from the MEMOBUS/Modbus register.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD9 (PPO input). A
value of 0 will disable the PZD9 (PPO input) load operation from the MEMOBUS/Modbus register.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD10 (PPO input). A
value of 0 will disable the PZD10 (PPO input) load operation from the MEMOBUS/Modbus register.
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
Description
Default
(Range)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0