T4: EZ Tuning

No.
Name
(Hex.)
T4-01
EZ Tuning Mode Selection
(3130)
T4-02
Motor Type Selection
(3131)
T4-04
Motor Rated Revolutions
(3133)
T4-05
Motor Rated Frequency
(3134)
T4-06
Motor Rated Voltage
(3135)
T4-07
Motor Rated Current
(3136)
T4-08
Motor Rated Capacity
(3137)
T4-09
Number of Poles
(3138)
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
Sets the type of Auto-Tuning for EZOLV control.
0 : Motor Parameter Setting
1 : Line-to-Line Resistance
Sets the type of motor.
0 : Induction (IM)
1 : Permanent Magnet (PM)
2 : Synchronous Reluctance (SynRM)
Sets rated rotation speed (min
-1
) of the motor.
Sets the rated frequency (Hz) of the motor.
Sets the rated voltage (V) of the motor.
Sets the rated current (A) of the motor.
Sets the motor rated power in the units set in o1-58 [Motor Power Unit Selection].
Sets the number of motor poles.
Description
3.16 T: Motor Tuning
Default
(Range)
0
(0, 1)
0
(0, 1, 2)
-
((40 Hz to 120 Hz) × 60 × 2/
E9-08)
Determined by E9-01 and
o2-04
(40.0 - 120.0 Hz)
200 V Class: 230.0 V,
400 V Class: 460.0 V
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
Determined by o2-04, C6-01
(10% to 200% of the drive
rated current)
Determined by E9-10
(0.10 - 650.00 HP)
Determined by E9-01
(2 - 120)