YASKAWA GA500 Maintenance & Troubleshooting page 80

Industrial ac microdrive
Table of Contents

Advertisement

2.8 Backup Function Operating Mode Display and Errors
Code
Name
rdEr
Error Reading Data
Code
Name
vAEr
Voltage Class, Capacity Mismatch
Code
Name
vFyE
Parameters do not Match
80
Causes
You tried to back up the data when o3-02 = 0 [Copy
Allowed Selection = Disabled].
Causes
The power supply specifications or drive capacity
parameter settings are different between the keypad
and the drive.
Causes
The parameters that are backed up in the keypad and
the parameters in the drive are not the same.
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
Possible Solutions
Set o3-02 = 1 [Enabled] and back up again.
Possible Solutions
1.
Make sure that drive model and the value set in o2-04 [Drive
Model (KVA) Selection] agree.
2.
Restore the parameters.
Possible Solutions
1.
Restore or backup the parameter again.
2.
Verify the parameters.

Advertisement

Table of Contents
loading

Table of Contents