1.5 Replace the Drive
1.
Wire the main circuit terminals.
Note:
To wire terminals +1 and +2, remove the jumper between terminals +1 and +2.
2.
Attach the wired control circuit board to the drive.
Push the control circuit board until the hooks click into place on the drive.
3.
Attach the keypad and front cover to the new drive.
4.
Energize the drive and set these parameters:
• o2-04 [Drive Model (KVA) Selection]: Set this parameter to the model number of the new drive.
• o4-01 to o4-13 [Maintenance Period]: Reset the performance life monitors for the components.