YASKAWA GA500 Maintenance & Troubleshooting page 186

Industrial ac microdrive
Table of Contents

Advertisement

3.18 Parameters that Change from the Default Settings with A1-02 [Control Method Selection]
No.
Maximum Output
E1-04
Frequency
E1-05
Maximum Output Voltage
E1-06
Base Frequency
E1-07
Mid Point A Frequency
E1-08
Mid Point A Voltage
Minimum Output
E1-09
Frequency
E1-10
Minimum Output Voltage
Overspeed Detection Delay
F1-09
Time
Motor Overload (oL1)
L1-01
Protection
KEB Start Voltage Offset
L2-31
Level
Stall Prevention during
L3-05
RUN
DC Bus Voltage Adjustment
L3-20
Gain
OVSuppression Accel/
L3-21
Decel P Gain
Current Suppression
L3-36
Gain@Accel
Speed Agree Detection
L4-01
Level
Speed Agree Detection
L4-02
Width
Speed Agree Detection
L4-03
Level(+/-)
Speed Agree Detection
L4-04
Width(+/-)
Carrier Freq Reduction Off-
L8-40
Delay
STPo Detection Level (Low
L8-90
Speed)
n5-04
Speed Response Frequency
Initial Pole Detection
n8-35
Method
Pull-in Current @
n8-51
Acceleration
Frequency Display Unit
o1-03
Selection
o1-04
V/f Pattern Display Unit
*1
The default setting changes when the setting for o2-04 [Drive Model Selection] changes.
*2
The default setting changes when the setting of C6-01 [Normal / Heavy Duty Selection] changes.
*3
The setting range changes when the setting of E5-01 [PM Motor Code Selection] changes when A1-02 = 5 [OLV/PM].
*4
The default setting changes when the drive model and E1-03 [V/f Pattern Selection] change.
*5
This is the value for 200 V class drives. Double the value for 400 V class drives.
When A1-02 = 5 [OLV/PM], the maximum value of the setting range is 100.0.
*6
*7
When A1-02 = 5 [OLV/PM], the setting range is -100.0 to +100.0.
186
Name
Range
*2 *3
40.0 - 400.0
*5
0.0 - 255.0
*3
0.0 - 400.0
*3
0.0 - 400.0
*5
0.0 - 255.0
*3
0.0 - 400.0
*5
0.0 - 255.0
0.0 - 2.0
0 - 4
*5
0 - 100
0 - 3
0.00 - 5.00
0.10 - 10.00
0.0 - 100.0
*6
0.0 - 400.0
0.0 - 20.0
-400.0 - +400.0
0.0 - 20.0
0.00 - 2.00
0 - 5000
0.00 - 500.00
0 - 2
0 - 200%
0 - 3
0 - 1
Unit
0.1 Hz
0.1 V
0.1 Hz
0.1 Hz
0.1 V
0.1 Hz
0.1 V
0.1 s
1
1 V
1
0.01
0.01
0.1
0.1
0.1
*7
0.1
0.1
0.01 s
1
0.00 Hz
1
1
1
1
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
Control Method (A1-02 Setting)
V/f
OLV
(0)
(2)
*4
60.0
60.0
*4
200.0
200.0
*4
60.0
60.0
*4
3.0
3.0
*4
15.0
11.0
*4
1.5
0.5
*4
9.0
2.0
-
-
2
2
0
0
1
1
1.00
0.30
1.00
1.00
10.0
20.0
0.0 Hz
0.0 Hz
2.0 Hz
2.0 Hz
0.0 Hz
0.0 Hz
2.0 Hz
2.0 Hz
0.50
0.50
-
-
-
-
-
-
0
0
0
0
-
-

Advertisement

Table of Contents
loading