2.5 Minor Faults/Alarms
Code
Name
Note:
• The drive detects this error if the DC bus voltage changes irregularly without regeneration.
• If the drive detects this error, the terminal assigned to H2-01 to H2-03 = 10 [MFDO Function Select = Alarm] will be ON.
• Use L8-05 [Input Phase Loss Protection Sel] to enable and disable PF detection.
Code
Name
PGo
Encoder (PG) Feedback Loss
Note:
• The drive detects this error if it does not receive the speed detection pulse signal from the encoder in the detection time set in F1-14 [Encoder Open-Circuit Detect Time].
• If the drive detects this error, the terminal assigned to H2-01 to H2-03 = 10 [MFDO Function Select = Alarm] will activate.
• If the drive detects this error, it will operate the motor as specified by the stopping method set in F1-02 [PG Open Circuit Detection Select].
Code
Name
rUn
Motor Switch during Run
Note:
If the drive detects this error, the terminal set to H2-01 to H2-03 = 10 [MFDO Function Selection = Alarm] will activate.
Code
Name
SE
Modbus Test Mode Error
Note:
If the drive detects this error, the terminal set to H2-01 to H2-03 = 10 [MFDO Function Selection = Alarm] will activate.
Code
Name
SToF
Safe Torque OFF Hardware
Note:
If the drive detects this error, the terminal set to H2-01 to H2-03 = 10 [MFDO Function Selection = Alarm] will activate.
Code
Name
TiM
Keypad Time Not Set
Note:
• Parameter o4-24 [bAT Detection Selection] enables and disables TiM detection.
• If the drive detects this error, the terminal set to H2-01 to H2-03 = 10 [MFDO Function Selection = Alarm] will activate.
Code
Name
TrPC
IGBT Maintenance Time (90%)
Note:
If the drive detects this error, the terminal set to H2-01 to H2-03 = 10 [MFDO Function Selection = Alarm] will activate.
68
Causes
The drive input power voltage is changing too much.
Unsatisfactory balance between voltage phases.
The main circuit capacitors have become
unserviceable.
Causes
The encoder cable is disconnected or wired
incorrectly.
The encoder is not receiving power.
The holding brake is stopping the motor.
Causes
The drive received a Motor 2 Selection [H1-xx = 16]
during run.
Causes
MEMOBUS/Modbus communications self-
diagnostics [H1-xx = 67] was done while the drive
was running.
Causes
One of the two terminals H1-HC and H2-HC received
the Safe Disable input signal.
The Safe Disable input signal is wired incorrectly.
There is internal damage to one Safe Disable channel.
Causes
There is a battery in the keypad, but the date and time
are not set.
Causes
The IGBT is at 90% of its expected performance life.
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
Possible Solutions
• Examine the supply voltage for problems.
• Make the drive input power stable.
• Examine the supply voltage for problems.
• Make the drive input power stable.
• If the supply voltage is good, examine the magnetic contactor on
the main circuit side for problems.
• Examine the capacitor maintenance time in monitor U4-05
[CapacitorMaintenance].
• If U4-05 is more than 90%, replace the capacitor. Contact
Yaskawa or your nearest sales representative for more
information.
• Examine the supply voltage for problems.
• Re-energize the drive.
• If the alarm stays, replace the circuit board or the drive. For
information about replacing the control board, contact Yaskawa
or your nearest sales representative.
Possible Solutions
Examine for wiring errors or disconnected wires in the encoder
cable, and repair problems.
Examine the encoder power supply.
Release the holding brake.
Possible Solutions
Make sure that the drive receives the Motor 2 Selection while the
drive is stopped.
Possible Solutions
Stop the drive and do MEMOBUS/Modbus communications self-
diagnostics.
Possible Solutions
• Make sure that the Safe Disable signal is input from an external
source to terminals H1-HC or H2-HC.
• When the Safe Disable function is not in use, use a jumper to
connect terminals H1-HC and H2-HC.
Replace the board or the drive. For information about replacing the
control board, contact Yaskawa or your nearest sales representative.
Possible Solutions
Set the date and time with the keypad.
Possible Solutions
Replace the IGBT or the drive. For information about replacing the