YASKAWA GA500 Maintenance & Troubleshooting page 49

Industrial ac microdrive
Table of Contents

Advertisement

Code
Name
oFA10
Option Card Error Occurred at
Option Port CN5
Note:
Do a Fault Reset to clear the fault.
Code
Name
Option Card Error Occurred at
oFA11
Option Port CN5
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFA12
Option Card Connection Error (CN5)
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFA13
Option Card Connection Error (CN5)
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFA14
Option Card Connection Error (CN5)
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFA15
Option Card Connection Error (CN5)
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFA16
Option Card Connection Error (CN5)
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFA17
Option Card Connection Error (CN5)
Note:
Do a Fault Reset to clear the fault.
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
Causes
A fault occurred in the option card.
Causes
A fault occurred in the option card.
Causes
A fault occurred in the option card.
Causes
A fault occurred in the option card.
Causes
A fault occurred in the option card.
Causes
A fault occurred in the option card.
Causes
A fault occurred in the option card.
Causes
A fault occurred in the option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.
2.4 Fault
2
49

Advertisement

Table of Contents
loading

Table of Contents