T: Motor Tuning; T0: Tuning Mode Selection; T1: Induction Motor Auto-Tuning - YASKAWA GA500 Maintenance & Troubleshooting

Industrial ac microdrive
Table of Contents

Advertisement

3.16

T: Motor Tuning

T0: Tuning Mode Selection

No.
Name
(Hex.)
T0-00
Tuning Mode Selection
(1197)

T1: Induction Motor Auto-Tuning

No.
Name
(Hex.)
T1-00
Motor 1/Motor 2 Selection
(0700)
T1-01
Auto-Tuning Mode Selection Sets the type of Auto-Tuning.
(0701)
T1-02
Motor Rated Power
(0702)
T1-03
Motor Rated Voltage
(0703)
T1-04
Motor Rated Current
(0704)
T1-05
Motor Base Frequency
(0705)
T1-06
Number of Motor Poles
(0706)
T1-07
Motor Base Speed
(0707)
T1-09
Motor No-Load Current
(0709)
T1-10
Motor Rated Slip Frequency Sets motor rated slip.
(070A)
T1-11
Motor Iron Loss
(070B)
T1-12
Test Mode Selection
(0BDB)
T1-13
No-load voltage
(0BDC)
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
Sets the type of Auto-Tuning.
0 : Motor Parameter Tuning
1 : Control Tuning
Sets which motor to tune when motor 1/2 switching is enabled.
You can only use the keypad to set this parameter. You cannot use external input terminals to set it.
Note:
This parameter is enabled when H1-xx = 16 [Motor 2 Selection] is set. When H1-xx ≠ 16 the
keypad will not show this parameter.
1 : Motor 1
2 : Motor 2
0 : Rotational Auto-Tuning
1 : Stationary Auto-Tuning 1
2 : Stationary Line-Line Resistance
Uses the units set in o1-58 [Motor Power Unit Selection] to set the motor rated output power.
Sets the rated voltage (V) of the motor. Enter the base speed voltage for constant output motors.
Sets the rated current (A) of the motor.
Sets the base frequency (Hz) of the motor.
Sets the number of motor poles.
Sets the motor base speed for Auto-Tuning (min
Sets the no-load current of the motor.
Sets the iron loss to calculate the energy-saving coefficient.
Sets the function to enable Test Mode after Stationary Auto-Tuning. When you can operate the motor
with a light load attached after Stationary Auto-Tuning is complete, enable this parameter.
Note:
You must first set T1-10 = 0 [Motor Rated Slip Frequency = 0 Hz] to enable this parameter.
0 : No
1 : Yes
Sets the no-load voltage of the motor. When the no-load voltage at rated speed is available, for
example on the motor test report, set the voltage in this parameter. If the no-load voltage is not
available, do not change this parameter.
Note:
• To get the same qualities as a Yaskawa 1000-series drive or previous series drive, set this
parameter = T1-03 [Motor Rated Voltage].
• The default setting is different for different models.
–B001 - B006, 2001 - 2008, 4001 - 4004: T1-03 × 0.85
–B010 - B018, 2010 - 2082, 4005 - 4060: T1-03 × 0.90
Description
Description
-1
(r/min)).

3.16 T: Motor Tuning

Default
(Range)
0
(0, 1)
Default
(Range)
1
(1, 2)
Determined by A1-02
(Determined by A1-02)
Determined by o2-04, C6-01
(0.00 - 650.00 HP)
Determined by o2-04, C6-01
(200 V Class: 0.0 - 255.5 V,
400 V Class: 0.0 - 511.0 V)
Determined by o2-04
(10% to 200% of the drive
rated current)
60.0 Hz
(0.0 - 590.0 Hz)
4
(2 to 120)
-1
1750 min
(r/min)
(0 - 35400 min
-1
(r/min))
-
(0A - T1-04; max. of 2999.9)
-
(0.000 - 20.000 Hz)
Determined by E2-10 or E4-
10
(0 - 65535 W)
0
(0, 1)
T1-03 × 0.9
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
169