HPE ProLiant DL385 Gen10 Plus v2 Maintenance And Service Manual page 95

Hide thumbs Also See for ProLiant DL385 Gen10 Plus v2:
Table of Contents

Advertisement

CAUTION:
CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-
sensitive devices. To prevent damage, observe antistatic precautions.
CAUTION:
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless all PCI slots have either an
expansion slot cover or an expansion board installed.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Do one of the following:
Extend the server from the rack .
Remove the server from the rack .
5. Remove the access panel .
CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the server
CAUTION:
in this manner results in improper airflow and improper cooling that can lead to thermal damage.
6. Remove the primaryPCIe riser cage.
7. Remove the DSC-25 card from the slot.
HPE ProLiant DL385 Gen10 Plus v2 Server Maintenance and Service Guide