HPE ProLiant DL385 Gen10 Plus v2 Maintenance And Service Manual page 52

Hide thumbs Also See for ProLiant DL385 Gen10 Plus v2:
Table of Contents

Advertisement

To replace the component, reverse the removal procedure.
Removing and replacing a power supply
Removing and replacing a power supply
Power supply warnings and cautions
Power supply warnings and cautions
WARNING:
WARNING:
To reduce the risk of electric shock or damage to the equipment:
Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
Unplug the power cord from the power supply to disconnect power to the equipment.
Do not route the power cord where it can be walked on or pinched by items placed against it. Pay particular
attention to the plug, electrical outlet, and the point where the cord extends from the server.
WARNING: To reduce the risk of injury from electric shock hazards, do not open power supplies. Refer all maintenance,
WARNING:
upgrades, and servicing to qualified personnel
CAUTION: Mixing different types of power supplies in the same server might:
CAUTION:
Limit or disable some power supply features including support for power redundancy.
Cause the system to become unstable and might shut down.
To ensure access to all available features, all power supplies in the same server should have the same output and
efficiency ratings. Verify that all power supplies have the same part number and label color.
Removing and replacing a hot-plug AC power supply
Removing and replacing a hot-plug AC power supply
WARNING:
WARNING:
To reduce the risk of personal injury, fire, or damage to the equipment, do not overload the AC supply branch circuit
that provides power to the rack. Consult the electrical authority having jurisdiction over wiring and installation
requirements of your facility.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives, power supplies, and internal system
WARNING:
components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server before beginning any installation
CAUTION:
procedure. Improper grounding can cause electrostatic discharge.
CAUTION:
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server or the enclosure unless all drive and
device bays are populated with either a component or a blank.
Procedure
Procedure
1. If installed, release the cable management arm .
2. If the server is using a single power supply only, remove all power from the server:
a. Back up all server data.