Specifications
Specifications
For more information on cable, power, environmental, compliance, and general specifications, see the HPE Compute Transceiver and
Cable Hardware Matrix.
Cable Hardware Matrix
Environmental specifications
Environmental specifications
Specification
Specification
1
Temperature range
Temperature range
Operating
Nonoperating
Relative humidity (noncondensing) —
Relative humidity (noncondensing)
Operating
Nonoperating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 304.8 m (1.8°F per 1000 ft) to 3048 m (10,000 ft)
is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper limit and rate of
change might be limited by the type and number of options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of 1.0°C per every 175 m (1.8°F
per every 574 ft) above 900 m (2953 ft) to a maximum of 3048 m (10,000 ft).
40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F per every 410 ft) above 900 m
(2953 ft) to a maximum of 3048 m (10,000 ft).
The approved hardware configurations for this system are listed on the Hewlett Packard Enterprise website
Value
Value
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
Minimum to be the higher (more moisture) of -12°C (10.4°F) dew point or 8% relative humidity
Maximum to be 24°C (75.2°F) dew point or 90% relative humidity
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature