Item
Item
Description
Description
23
Chassis Intrusion Detection connector
24
Dual USB port
25
Flexible Smart Array connector
26
Tertiary (processor 2) PCI riser connector
27
Secondary (processor 2) PCIe riser connector
28
System battery
29
Serial port connector
System maintenance switch descriptions
System maintenance switch descriptions
Position
Position
Default
Default
1
S1
Off
S2
Off
S3
Off
S4
Off
S5
Off
2 3
S6 ,
Off
S7
Off
S8
S9
S10
S11
S12
1
To access the redundant ROM, set S1, S5, and S6 to On.
2
When the system maintenance switch position 6 is set to the On position, the system is prepared to restore all configuration settings
to their manufacturing defaults.
3
When the system maintenance switch position 6 is set to the On position and Secure Boot is enabled, some configurations cannot be
restored. For more information, see
Secure Boot
.
DIMM label identification
DIMM label identification
To determine DIMM characteristics, see the label attached to the DIMM. The information in this section helps you to use the label to
Function
Function
Off = iLO security is enabled.
On = iLO security is disabled.
Reserved
Reserved
Reserved
Off = Power-on password is enabled.
On = Power-on password is disabled.
Off = No function
On = Restore default manufacturing settings
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
HPE ProLiant DL385 Gen10 Plus v2 Server Maintenance and Service Guide
133