9. Install all components removed from the failed system board.
10. Install the access panel.
11. Install the power supplies.
12. Power up the server.
13. Ensure all firmware, including option cards and embedded devices, is updated to the same versions to ensure that the latest drivers
are being used.
14. Re-enter any Secure Boot Keys that were previously added in the Secure Boot configuration.
15. Re-enter the server serial number and product ID .
Re-entering the server serial number and product ID
Re-entering the server serial number and product ID
After replacing the system board, re-enter the system serial number and product ID, and configure the date and time settings.
Procedure
Procedure
1. Access the UEFI System Utilities. During POST, press F9 F9.
2. From the System Utilities screen, select System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options >
Advanced Service Options.
3. Select Serial Number, and then press Enter
The following warning appears:
The serial number is modified by qualified service personnel and must match the serial
number located on the chassis.
4. Click OK.
5. Type the serial number, and then press Enter
6. Select Product ID, and then press Enter
The following warning appears:
Product ID is modified only by qualified service personnel. This value must match the
Enter.
Enter.
Enter.
HPE ProLiant DL385 Gen10 Plus v2 Server Maintenance and Service Guide
115