To replace the component, reverse the removal procedure.
Removing and replacing an expansion slot blank
Removing and replacing an expansion slot blank
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove power from the
WARNING:
server by removing the power cord. The front panel Power On/Standby button does not shut off system power.
Portions of the power supply and some internal circuitry remain active until AC power is removed.
CAUTION: For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers, or
CAUTION:
blanks installed. If the server supports hot-plug components, minimize the amount of time the access panel is open.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
Extend the server from the rack .
Remove the server from the rack .
4. Remove the access panel .
5. Remove the PCIe riser cage:
Remove the primary PCIe riser cages
Remove the secondary and tertiary PCIe riser cage
6. Remove the expansion slot blank.