Choosing The Cable Pairing Convention - Agilent Technologies WireScope 350 User Manual

Hide thumbs Also See for WireScope 350:
Table of Contents

Advertisement

5 Select the performance grade of the connector, if known, and press

Choosing the Cable Pairing Convention

To identify the correct pair in the test results, the WireScope must be
told what cable pairing convention is used. For example, if the 3,6 pair
fails a test, it would be "Pair 2" if using T568A pairing, but it would be
"Pair 3" if using T568B pairing.
1 On the Autotest Setup screen, press Cable Pairing, then press Edit.
2 Press the cable pairing convention used on the job, then press OK.
OK. The Autotest Setup screen displays, with the new connector type
nest to the connector icon.
The Cable Pairing Setup screen displays.
The Autotest Setup screen displays, with the cable pairing convention
named.
8r…‡vs’vtÃ8‚ƒƒr…Ã8hiyvt
Tr‡‡vtÃVƒÃhÃ6ˆ‡‚‡r†‡
3−17