To run a self test on the DualRemote 350:
1 Insert the Self-Test probe in the SmartProbe port of the DualRemote
2 Press the OK key. The Pass/Fail LED on the front panel of the
If the self test fails, the DualRemote 350 requires a new baseline
calibration or repair. Contact Agilent Technical Support (see Technical
Support, on page 1-21).
Touch-Screen Calibration
If it seems that the WireScope 350 is not responding correctly to taps on
the touch screen, you may need to calibrate the touch screen to bring it
into alignment with the underlying display.
To calibrate the touch screen:
1 Ensure that you have the stylus available.
2 On the Main Menu, press System. The System Settings screen
3 On the System Settings screen, press Calibrate Touch Screen, then
4 Using the stylus, press the screen where the onscreen instructions
When the calibration is complete, the System Settings screen displays.
350.
DualRemote 350 indicates the outcome of the self test.
displays.
press Edit. A Calibration screen displays.
direct.
Srsr
rpr
8hyvi
hv
8−7