SHUTDOWN ALARM

When controller detects shutdown alarm, it will send signal to stop the generator.
No.
Shutdown
1
Emergency Stop
2
Over Speed
3
Under Speed
4
Loss of Speed Signal
5
Gen Over Frequency
6
Gen Under Frequency
7
Gen Over Voltage
8
Gen Under Voltage
9
Fail to Start
10
Gen Over Current
11
Maintenance Due
12
ECU shutdown
13
ECU Comm. Fail
14
Reverse Power
15
Over Power
16
Temp. Sensor Open
17
High Temp.
Oil Pressure Sensor
18
Open
HGM9600 Series Genset Controller User Manual
Table 9 Shutdown Alarms
When controller detects emergency stop signal, it will send a stop
signal.
When controller detects the speed value is higher than the set value,
it will send a stop signal.
When controller detects the speed value is lower than the set value,
it will send a stop signal.
When controller detects speed value equals to 0, and the action
select "Shutdown", it will send a stop alarm signal
When controller detects the frequency value is higher than the set
value, it will send a stop signal.
When controller detects the frequency value is lower than the set
value, it will send a stop signal.
When controller detects the voltage value is higher than the set
value, it will send a stop signal.
When controller detects the voltage value is lower than the set value,
it will send a stop signal.
If genset start fail within setting of start times, controller will send a
stop signal.
When controller detects the current value is higher than the set
value, it will send a stop signal.
When count down time is 0 and the action select "Shutdown", it will
send a stop alarm signal.
When controller gets stop signal from engine via J1939, it will send a
stop signal.
When controller NOT gets data from engine via J1939, it will send a
stop signal.
When controller detects reverse power value (power is negative) is
lower than the set value, and the reverse power action select
"shutdown", it will send a stop alarm signal.
When controller detects reverse power value (power is positive) is
higher than the set value, and the reverse power action select
"shutdown", it will send a stop signal.
When controller detects sensor is open circuit, and the action select
"shutdown", it will send a stop signal.
When controller detects temperature is higher than the set value, it
will send a stop signal.
When controller detects sensor is open circuit, and the action select
"shutdown", it will send a stop signal.