Wirings Connection - Smartgen HGM9600 Series User Manual

Genset controller
Table of Contents

Advertisement

7 WIRINGS CONNECTION

HGM9600 series controller's rear as following:
No.
Function
1
B-
2
B+
3
Emergency Stop
4
Fuel Relay Output
5
Start Relay Output
6
Aux. Output 1
7
Aux. Output 2
8
Aux. Output 3
9
Charger(D+)
10
Aux. Input 1
11
Aux. Input 2
12
Aux. Input 3
13
Aux. Input 4
14
Aux. Input 5
HGM9600 Series Genset Controller User Manual
Fig.3 HGM9600 Rear Panel
Table 12 Description of Terminal Connection
Cable Size
2.5mm
2
Connected with negative of starter battery
Connected with positive of starter battery. If wire length
2
2.5mm
is over 30m, better to double wires in parallel. Max. 20A
fuse is recommended
2.5mm
2
Connected with B+ via emergency stop button
1.5mm
2
B+ is supplied by 3 terminal, rated 16A
B+ is supplied by 3 terminal,
2
1.5mm
rated 16A
B+ is supplied by 2 terminal,
1.5mm
2
rated 7A
B+ is supplied by 2 terminal,
2
1.5mm
rated 7A
B+ is supplied by 2 terminal,
2
1.5mm
rated 7A
Connected with charger starter's D+ (WL) terminals.
1.0mm
2
Being hang up If there is no this terminal
1.0mm
2
Ground connected is active (B-)
1.0mm
2
Ground connected is active (B-)
1.0mm
2
Ground connected is active (B-)
1.0mm
2
Ground connected is active (B-)
2
1.0mm
Ground connected is active (B-)
Remarks
Connected
starter coil
Details see
14
Details see Table
15
Page 29 of 73
to
Table

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hgm9610Hgm9620