SHUTDOWN ALARM

When controller detects shutdown alarm, it will send signal to open switch and stop genset. The
alarms are displayed in LCD.
No.
Items
1
Emergency Stop
2
High Temp.
3
Low Oil Pressure
4
Over Speed
5
Under Speed
6
Loss of Speed Signal
7
Gen Over Voltage
8
Gen Under Voltage
9
Gen Over Current
10
Failed to Start
11
Gen Over Freq.
12
Gen Under Freq.
13
No Gens
14
Low Fuel Level
15
Low Coolant Level
16
Temp. Sensor Open
17
OP Sensor Open
18
Maintenance Due
HGM6100LT Series Genset Controller User Manual
Table 5 – Shutdown Alarms
When controller detects emergency stop signal, it will send a shutdown
alarm signal and it will be displayed in LCD.
When the temperature of water/cylinder is higher than set threshold,
controller will send a shutdown alarm signal and it will be displayed in
LCD.
When oil pressure is lower than threshold, controller will send a
shutdown alarm signal and it will be displayed in LCD.
When genset speed is higher than set threshold, controller will send a
shutdown alarm signal and it will be displayed in LCD.
When genset speed is lower than set threshold, controller will send a
shutdown alarm signal and it will be displayed in LCD.
When speed is 0 and delay is not 0, controller will send a shutdown
alarm signal and it will be displayed in LCD.
When genset voltage is higher than threshold, controller will send a
shutdown alarm signal and it will be displayed in LCD.
When genset voltage is under set threshold, controller will send a
shutdown alarm signal and it will be displayed in LCD.
When genset current is higher than set threshold and delay is not 0, it
will send a shutdown alarm signal and it will be displayed in LCD.
Within set start times, if failed to start, controller will send a shutdown
alarm signal and it will be displayed in LCD.
When genset frequency is higher than set threshold, controller will send
a shutdown alarm signal and it will be displayed in LCD.
When genset frequency is lower than set threshold, controller will send a
shutdown alarm signal and it will be displayed in LCD.
When genset frequency is 0, controller will send a shutdown alarm signal
and it will be displayed in LCD.
When low fuel level input is active, controller will send a shutdown alarm
signal and it will be displayed in LCD.
When genset coolant level low input is active, controller will send a
shutdown alarm signal and it will be displayed in LCD.
When sensor hasn't connected to corresponding port, controller will
send shutdown alarm signal and it will be displayed in LCD.
When sensor hasn't connected to corresponding port, controller will
send shutdown alarm signal and it will be displayed in LCD.
Maintenance type is running time. When genset running time is longer
Description