Table 58: Parts Required for Connecting an EX Series Switch to Earth Ground
Switch
Earthing
Terminal
Location
EX2300
Rear panel of
the chassis
Grounding
Grounding Lug
Cable
Specifications
Requirements
EX2300
EX2300
switches
switches except
except
EX2300-24MP
EX2300-24
and
MP and
EX2300-48MP
EX2300-48
models—Panduit
MP models
LCC10-14AW-L
—14 AWG
or equivalent—
(2 mm²),
not provided
minimum
EX2300-24MP
90°C wire,
and
or as
EX2300-48MP
permitted by
models—Panduit
the local
LCA10-10L or
code
equivalent—not
EX2300-24
provided
MP and
EX2300-48
MP models
—14-10
AWG STR
(2.5-6 mm²),
12-10 AWG
SOL (4-6
mm²)
minimum
90°C wire,
or as
permitted by
the local
code—not
provided
(Continued)
Screws and
Additional
Washers
Information
EX2300
switches
except
EX2300-24
MP and
EX2300-48
MP models
Two
10-32
x .25 in.
screws
with #10
split-lock
washer—
not
provided
Two #10
flat
washers
—not
provided
EX2300-24
MP and
EX2300-48
MP models
One Pan
Phillips
M 4 x 6
mm
Nickel
plated
screw—
provided
166