Juniper EX9214 Hardware Manual page 183

Hide thumbs Also See for EX9214:
Table of Contents

Advertisement

Table 59: Special Instructions to Follow Before Connecting Earth Ground to an EX Series Switch
Switch
Special Instructions
EX2300-C
You must install the EX2300-C in a restricted-access location and ensure that the chassis is
always properly grounded. The EX2300-C has a two-hole protective grounding terminal
provided on the chassis. Under all circumstances, use this grounding connection to ground
the chassis. For AC-powered systems, you must also use the grounding wire in the AC
power cord along with the two-hole grounding lug connection. This tested system meets or
exceeds all applicable EMC regulatory requirements with the two-hole protective
grounding terminal.
EX3200 and
Some early variants of EX3200 and EX4200 switches for which the Juniper Networks
EX4200
model number on the label next to the protective earthing terminal is from 750-021
through 750-030
xxx require 10-24x.25 in. screws.
172
xxx

Advertisement

Table of Contents
loading

Table of Contents