Juniper EX9214 Hardware Manual page 243

Hide thumbs Also See for EX9214:
Table of Contents

Advertisement

1. Verify that the installation is successful and the EX9200-SF2 is online by issuing the show chassis
environment cb command:
user@switch> show chassis environment cb 0
CB 0 status
State
Online
Temperature
30 degrees C / 86 degrees F
...
user@switch> show chassis environment cb 1
CB 1 status
State
Online
Temperature
30 degrees C / 86 degrees F
...
Other details, such as, temperature, power, etc are also displayed along with the state.
2. Verify that the fabric planes come online correctly by issuing the show chassis fabric summary command:
user@switch> show chassis fabric summary
Plane
State
Uptime
0
Online
2 days, 19 hours, 10 minutes, 9 seconds
1
Online
2 days, 19 hours, 10 minutes, 9 seconds
...
3. Verify that the backup Routing Engine is back online by issuing the show chassis routing-engine 1
command:
user@switch> show chassis routing-engine 1
Routing Engine Status:
Slot 1:
Current State
...
4. Verify that the EX9200-SF2s appear in output from the show chassis hardware command:
user@switch> show chassis hardware
Hardware inventory:
Item
Version Part number Serial number
Chassis
Midplane
REV 01
FPM Board
REV 04
Backup
JN1221A03RFC
750-053633
ACRA1451
760-021392
ABCB4822
Description
EX9204
EX9204-BP
Front Panel Display
232