Juniper EX9214 Hardware Manual page 182

Hide thumbs Also See for EX9214:
Table of Contents

Advertisement

Table 58: Parts Required for Connecting an EX Series Switch to Earth Ground
Switch
Earthing
Terminal
Location
EX9251
Rear panel of
the chassis
EX9253
Right side of
the chassis
Tools required for connecting an EX Series switch to earth ground:
• An electrostatic discharge grounding strap (provided)
• A Phillips (+) number 2 screwdriver to tighten the screws.
An AC–powered EX Series switch gains additional grounding when you plug the power supply in the
switch into a grounded AC power outlet by using an AC power cord appropriate for your geographical
location.
Special Instructions to Follow Before Connecting Earth Ground to an EX Series Switch
Table 59 on page 172
lists the special instructions that you might need to follow before connecting
earth ground to a switch.
Grounding
Grounding Lug
Cable
Specifications
Requirements
12 AWG
Panduit
(2.5 mm²),
LCD10-10A-L or
minimum 90° C
equivalent—
wire, or one
not provided
that complies
with the local
code—
not provided
14-10 AWG
Panduit
(2-5.3 mm²),
LCD10-14B-L or
minimum 90° C
equivalent—
wire, or one
provided
that complies
with the local
code—
not provided
(Continued)
Screws and
Additional
Washers
Information
Two 10-32
See
Grounding
screws—
Cable and Lug
provided
Specifications for
EX9200
Two M5 Pan
Head screws—
provided
171
Switches.

Advertisement