Table 61: Chassis Component Alarm Conditions on EX9200 Switches
Chassis
Alarm Condition
Component
Chassis temperature has
exceeded 167° F (75° C). If this
condition persists for more
than four minutes, the switch
shuts down.
The temperature sensor has
failed.
Backup Routing Engine Alarms
For switches with primary and backup Routing Engines, a primary Routing Engine can generate alarms
for events that occur on a backup Routing Engine.
for events that occur on a backup Routing Engine.
NOTE: Because the failure occurs on the backup Routing Engine, alarm severity for some events
(such as Ethernet interface failures) is yellow instead of red.
NOTE: For information about configuring redundant Routing Engines, see the
Availability Library for Routing
Alarm
Severity
Major (red)
Major (red)
Table 62 on page 300
Devices.
(Continued)
Remedy
Check room temperature.
Check air filter and replace it, if
required.
Check airflow.
Check fan.
Open a support case using the Case
Manager link at
https:/ /www.juniper.net/
support/
or call 1-888-314-5822 (toll free,
US & Canada) or 1-408-745-9500 (from
outside the United States).
lists chassis alarms generated
Junos OS High
299