Description
This command sets or gets the st serial interface control signal (send timing:
clock) to normal or inverted. The default setting is "normal" .
Syntax
st <normal|inverted|get>
Parameter
Definition
normal
Sets the signal to normal (falling edge sends data).
inverted
Sets the signal to inverted (rising edge sends data).
get
Returns the current setting for this option (normal or
inverted).
Example
st get
User Interface Screen Location
System Info > Admin Setup > Video Network > Advanced V.35: ST
V.35/RS-449/RS-530 Commands