critical temperature level before an orderly shutdown occurs, the server performs an immediate shutdown.
When the Thermal Shutdown feature is disabled in the BIOS/Platform Configuration (RBSU), iLO does not perform an orderly shutdown
when a cautionary temperature level is detected. Disabling this feature does not disable the server hardware from performing an
immediate shutdown when a critical temperature level is detected.
CAUTION: A thermal event can damage server components when the Thermal Shutdown feature is disabled in the
CAUTION:
BIOS/Platform Configuration (RBSU).
Installing high-performance fans
Installing high-performance fans
About this task
About this task
CAUTION: Caution: To prevent damage server, ensure that all DIMM latches are closed and locked before installing the fans.
CAUTION:
CAUTION:
CAUTION:
Do not operate the server for long periods with the access panel open or removed. Operating the server in this manner
results in improper airflow and improper cooling that can lead to thermal damage.
Procedure
Procedure
1. Extend the server from the rack .
2. Remove the access panel .
3. If installed, remove all fan blanks.
4. Remove all standard fans.
IMPORTANT: Do not mix standard and high performance fans in the same server.
IMPORTANT:
HPE ProLiant DL380 Gen11 Server User Guide
59