System power LED
Health LED
Systems Insight Display
Systems Insight Display
Health
Health
LED and color
LED and color
LED
LED
Processor (amber)
Red
Processor (amber)
Amber
DIMM (amber)
Red
DIMM (amber)
Amber
Over temp (amber)
Amber
Over temp (amber)
Red
PCI riser (amber)
Red
Fan (amber)
Amber
Fan (amber)
Red
Power supply (amber)
Red
Power supply (amber)
Amber
Power cap (off)
System
System
Status
Status
power LED
power LED
Amber
One or more of the following
conditions might exist:
Processor in socket X has failed.
Processor X is not installed in
the socket.
Processor X is unsupported.
ROM detects a failed processor
during POST.
Green
Processor in socket X is in a pre-
failure condition.
Green
One or more DIMMs have failed.
Green
DIMM in slot X is in a pre-failure
condition.
Green
The Health Driver has detected a
cautionary temperature level.
Amber
The server has detected a hardware
critical temperature level.
Green
The PCI riser cage is not seated
properly.
Green
One fan has failed or has been
removed.
Green
Two or more fans have failed or
been removed.
Amber
One or more of the following
conditions might exist:
Only one power supply is
installed and that power supply
is in standby.
Power supply fault.
System board fault.
Green
One or more of the following
conditions might exist:
Redundant power supply is
installed and only one power
supply is functional.
AC power cord is not plugged
into redundant power supply.
Redundant power supply fault.
Power supply mismatch at
POST or power supply
mismatch through hot-plug
addition.
Amber
Standby.