HPE ProLiant DL380 Gen11 User Manual page 233

Hide thumbs Also See for ProLiant DL380 Gen11:
Table of Contents

Advertisement

Troubleshooting resources
Troubleshooting resources
Troubleshooting resources are available for HPE Gen11 server products in the following documents:
Troubleshooting Guide for HPE ProLiant Gen11 servers provides procedures for resolving common problems and comprehensive
courses of action for fault isolation and identification, issue resolution, and software maintenance.
Error Message Guide for HPE ProLiant Gen11 servers and HPE Synergy provides a list of error messages and information to assist with
interpreting and resolving error messages.
Integrated Management Log Messages and Troubleshooting Guide for HPE ProLiant Gen11 servers and HPE Synergy provides IML
messages and associated troubleshooting information to resolve critical and cautionary IML events.
To access troubleshooting resources for your product, see the Hewlett Packard Enterprise website
Specifications
Specifications
Subtopics
Subtopics
Environmental specifications
Environmental specifications
Mechanical specifications
Mechanical specifications
Power supply specifications
Power supply specifications
Hot-plug power supply calculations
Hot-plug power supply calculations
Environmental specifications
Environmental specifications
Specification
Specification
1
Temperature range
Temperature range
Operating
Nonoperating
Relative humidity (noncondensing) —
Relative humidity (noncondensing)
Operating
Nonoperating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 304.8 m (1.8°F per 1000 ft) to 3048 m (10,000 ft) is
applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper limit and rate of change
might be limited by the type and number of options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of 1.0°C per every 175 m (1.8°F per
every 574 ft) above 900 m (2953 ft) to a maximum of 3048 m (10,000 ft).
40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F per every 410 ft) above 900 m
Hewlett Packard Enterprise website .
Value
Value
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
Minimum to be the higher (more moisture) of -12°C (10.4°F) dew point or 8% relative humidity
Maximum to be 24°C (75.2°F) dew point or 90% relative humidity
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature