HPE ProLiant DL380 Gen11 User Manual page 103

Hide thumbs Also See for ProLiant DL380 Gen11:
Table of Contents

Advertisement

Results
Results
The installation is complete.
Power supply options
Power supply options
Subtopics
Subtopics
Power supply warnings and cautions
Power supply warnings and cautions
Hot-plug power supply calculations
Hot-plug power supply calculations
Installing an AC power supply
Installing an AC power supply
Power supply warnings and cautions
Power supply warnings and cautions
WARNING:
WARNING:
To reduce the risk of electric shock or damage to the equipment:
Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
Unplug the power cord from the power supply to disconnect power to the equipment.
Do not route the power cord where it can be walked on or pinched by items placed against it. Pay particular attention
to the plug, electrical outlet, and the point where the cord extends from the server.
WARNING: To reduce the risk of injury from electric shock hazards, do not open power supplies. Refer all maintenance,
WARNING:
upgrades, and servicing to qualified personnel
CAUTION:
CAUTION: Mixing different types of power supplies in the same server might:
Limit or disable some power supply features including support for power redundancy.
Cause the system to become unstable and might shut down.
To ensure access to all available features, all power supplies in the same server should have the same output and efficiency
ratings. Verify that all power supplies have the same part number and label color.
Hot-plug power supply calculations
Hot-plug power supply calculations
For hot-plug power supply specifications and calculators to determine electrical and heat loading for the server, see the Hewlett Packard
Enterprise Power Advisor website (https://www.hpe.com/info/poweradvisor/online
Installing an AC power supply
Installing an AC power supply
Prerequisites
Prerequisites
Before installing a power supply option, review the Power supply warnings and cautions.
https://www.hpe.com/info/poweradvisor/online).