SFF basic drive carrier
SFF
basic drive carrier
The SFF basic drive carrier supports hot-plug SAS, SATA, and U.3 NVMe drives .
Item
Item
LED
LED
1
Fault/Locate
2
Online/Activity
State
State
Solid amber
Solid blue
Flashing amber/blue (1
flash per second)
Flashing amber (1 flash per
second)
Off
Solid green
Flashing green (1 flash per
second)
Flashing green (4 flashes
per second)
Off
Definition
Definition
This drive has failed, is unsupported, or is invalid.
The drive is operating normally and being identified by a
management application.
The drive has failed, or a predictive failure alert has been received
for this drive. The drive has also been identified by a management
application.
A predictive failure alert has been received for this drive. Replace
the drive as soon as possible.
The drive is operating normally and not being identified by a
management application.
The drive is online and has no activity.
The drive is doing one of the following:
Rebuilding or performing a RAID
Performing a stripe size migration
Performing a capacity expansion
Performing a logical drive extension
Erasing
Spare part activation
The drive is operating normally and has activity.
The drive is not configured by a RAID controller or is a spare
drive.
HPE ProLiant ML350 Gen11 Server User Guide