Before installing the HPE Smart Storage Hybrid Capacitor, verify that the system BIOS meets the minimum firmware requirements to
support the capacitor pack.
IMPORTANT:
IMPORTANT:
If the system BIOS or controller firmware is older than the minimum recommended firmware versions, the capacitor
pack will only support one device.
The capacitor pack is fully charged after the system boots.
Subtopics
Subtopics
Minimum firmware versions
Minimum firmware versions
Minimum firmware versions
Minimum firmware versions
Product
Product
Server system ROM
HPE MR type-o and type-p Gen11 controllers 52.22.3-4650
HPE SR900 series type-p Gen11 controllers
Installing an energy pack
Installing an energy pack
Prerequisites
Prerequisites
Make sure that a compatible type-p storage controller is installed .
Make sure that you have the following items availables:
Storage controller backup power cable (ships with the storage controller)
Energy pack extension cable (P58199-B21)
If you are installing the HPE Smart Storage Hybrid Capacitor, verify that the system meets the minimum firmware requirements .
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up .
If the server is in rack mode, remove the server from the rack .
5. Remove the access panel .
6. If installed, remove the HPE NS204i Boot Device .
7. Connect the energy pack extension cable to the energy pack cable.
8. Install the energy pack:
a. Insert the energy pack at an angle (callout 1).
Minimum firmware version
Minimum firmware version
1.20
03.01.14.062
HPE ProLiant ML350 Gen11 Server User Guide
115